Winter weather is on the move here in the Gulf Coast Region and NOW is the time to get that end-of-year deferred and preventative maintenance DONE!
For example, one of our tremendous customers needed refurbishment on this Summit 2196R (CD4 3×3-10, Tapered Bore) Recessed Impeller Pump and we were happy to help! ABET technicians disassembled, inspected, and decontaminated the entire pump, inside and out.
Then they replaced the shaft assembly with a Summit 2196MTO kit, inclusive of bearings, isolators, 316SS shaft, thrust bearing housing, spanner nut/washer, and O-ring. They also replaced the other components, including the mechanical seal using an ASI 585-2/1.75 and TC/SC Viton O-rings.
Finally, they reassembled the pump and conducted a final inspection and hydrostatic pressure test.
The results are pictured here in preparation for delivery to our customer.
JOB COMPLETE!
Don’t wait and deal with a failed pump at the worst possible time: call your local partners at ABET and let’s prevent a problem from happening. We invite you to reach out to us at the shop ANY TIME or via the portal on our website. Our skilled technicians will manage everything and return both a repaired pump and peace of mind!
(And remember, if emergency repairs ARE needed, ABET has your back and we are available 24/7/365 – just give us a call!)
Experienced, Trusted, Local.
hashtag#TeamABET, hashtag#SummitPump, hashtag#AdvancedSealing International
ABET Distributing, USA
Summit Pump
Advanced Sealing International
INFORMATION REQUEST FORM
SALES
713-213-8091
REPAIRS & SERVICE
832-940-2070
ON CALL 24/7
713-213-8091
SERVICE CENTER
5003 Shank Rd
Pearland, TX 77581
Phone: 832-940-2070
SERVICE CENTER HOURS:
7:00 AM – 3:30 PM (Monday – Friday)
BUSINESS OFFICE
22136 Westheimer Parkway #238
Katy, TX 77450
Phone: 713-213-8091
BUSINESS OFFICE HOURS:
8:00 AM – 6:30 PM (Monday – Friday)